Automatic Western Blotter XD236
The automatic western blotting instrument is an intelligent automatic operation protein (immune) blotting (Western blot) instrument, the product is suitable for the automatic operation of western blotting or other similar method kits.
Retail price
$ 0
Market price
$ 0
Category:
重量
0
Stock:
0
隐藏域元素占位
- Product Detail
- Accessories
- Technical Specification
- Product Tags
-
Product Description
The automatic western blotting instrument is an intelligent automatic operation protein (immune) blotting (Western blot) instrument, the product is suitable for the automatic operation of western blotting or other similar method kits.
- No guard is required when running
- Chinese and English man-machine dialogue
- Can detect 36 bands at the same time
- New high and low double liquid level oblique mouth negative pressure suction nozzle to ensure that the instrument is free of crossover and pollution.
- Fully enclosed piping system, with safety guarantee for operators.
- Can lock the pre-programmed program and unlock the pre-programmed program.
- Prompt alarm function.
Clinical Application
- Mainly used for protein (Immuno) blotting or other similar methods for automated operation of kits.
- Autoimmune diseases: ENA, ANA, autoimmune liver disease, diabetes autoantibodies
- Viral infection: HIV, HCV, HEV, human T lymphocyte virus, etc.
- Bacteria and parasitic infections: Helicobacter pylori (HP), spirochetes, syphilis, toxoplasma, etc.
- Specific allergens
Product Specifications
Test strip capacity
1-36 or 1-30 strips
programming capacity
≥ 38+2(cured a program)
liquid distribution system of liquid distribution system
6 channel
distribution range of liquid pump
0000μL – 3000μL / 1μL Increment 0000μL - 3000μL / 1μL
quantitative correction
Semi automatic quantitative correction
Incubation time / increment
0 h – 24 h / 1 min recyclable
The incubation time display
hours minutes and seconds (hour min second)
Rocking speed
3 gear optional
Communication
RS232 interface specification baud rate 9600 data bit 8 stop bit 1 parity check NO
The capacity of the reagent bottle
200 mL × 5
The volume of the washing bottle
1000 mL × 1
The volume of the waste liquid bottle
2000 mL× 1(no leaky closed negative pressure waste liquid bottle)
Power supply
AC 220V ±22V ;50Hz±1 Hz
Rated power
< 250VA
accuracy of the reagent distribution of the liquid dispensing pump
+ 3% (when the distribution of the reagents of each channel is 2000 mu L)
Precision of the liquid pump reagent dispensing
CV ≤5%(when the channel allocation amount of reagent is 2000 L)
The temperature control of the rocking bed
The temperature at room temperature and constant temperature 37℃、30℃、25℃
Temperature control accuracy
± 1..5℃
Cross contamination
When negative and positive samples are tested in alternating order, negative samples should not be presented with positive strip operation. According to the requirements of protein imprinting kit and testing procedure set.
Pre test
reagents preparation and pipeline cleaning before use
Test
add sample by hand
Results interpretation
According to the requirements of the kit and / or instrument operation instructions, the standard strip, manual or instrumental interpretation
Previous